INSTALLATION
..........................................................................................................................................................................................................

Devices for Ex zone 2 (EC 921 and EC 922)

The versions for Ex zone 2 may not be operated in Ex zone 1. In Ex zone 2 it is not nec-
essary to provide electrical isolation in order to connect other equipment. If the devices
are powered externally, make sure that the power supply is correct. A device with a 24
V power pack may not be connected to 230 V. The connection schema shown in the
figure below corresponds to the latest revision 8.
28
L/
N/+
Batt
PE
Power supply
Make sure that the device is earthed (earthing screw on the right side)! In order to connect the de-
vice to the equipotential bonding, use a wire diameter of 4 mm².
..........................................................................................................................................................................................................
Power pack
+
+
01
02
Digital outputs
+
+
+
Vo
E4
C3
channel
Enco
Digital inputs
+
+
+
03
04
E5
Digital inputs 5 to 8
+ +
+
+
Ref.
Measuring
channel
Volume meter
Modem or
Ethernet con-
nection
Earthing screw
+
+
+
E6
E7
E8
+
+
Iin1
Iin2
PT 1000
Current in-
puts