List of parameters and operating modes

The following tables show the setting options for the operating modes in parentheses and separat-
ed with vertical lines, e.g. {Off|0-4.5V|4-20mA|Default}.
If the relevant fields are addressed by an external program, appropriate numerical values (position)
are to be assigned to the texts. In the example above this would be:
0 = Off, 1 = 0-4.5V, 2 = 4-20mA, 3 = Default

Screen: CUSTOMIZED DISPLAY

+Contrast
>Current load
>p
>t
>C
>K
>Vm
>Vb
>VmD
< CUSTOMIZED DISPLAY>
The customized display comprises a total of 9 possible displays. The display lines for the contrast
and the current load are permanently set. The operator can select the other 7 display lines in any
order from a list of maximum 14 values. The following values are available for selection:
Totalizer for the volume at base conditions (Vb)
Totalizer for the volume at measurement conditions (Vm)
VO totalizer
Totalizer for the volume at measurement conditions - customer (VmL)
Totalizer for the volume at base conditions - disturbance quantity (VbD)
Totalizer for the volume at measurement conditions - disturbance quantity (VmD)
Pressure (p)
Temperature (t)
Conversion factor (C)
K coefficient
Supercompressibility
Flow rate at measurement conditions
Flow rate at base conditions
Time
In order to set the customized display, see screen 3.5.0.0.
..........................................................................................................................................................................................................
Extended customized display
(contrast setting see page 34).
Quantities for the current measuring period and the current day
Customized value 1 displayed (default: p)
Customized value 2 displayed (default: tm)
Customized value 3 displayed (default: C)
Customized value 5 displayed (default: K)
Customized value 5 displayed (default: Vm)
Customized value 6 displayed (default: Vb)
Customized value 7 displayed (default: VmD)
"CUSTOMIZED DISPLAY" book
OPERATION
59