On-the-fly calibration

..........................................................................................................................................................................................................
1. Press " " to jump to the totalizer display and select
any totalizer.
2. The visible window will open even if another totalizer
is selected. Now select "On-the-fly calibr.".
3. Press Enter to start on-the-fly calibration. Now the
TVm and TVb totalizers will start to run together with
a stopwatch (Test time). If you press Enter once
again, this will stop on-the-fly calibration, and if you
press Enter another time, the totalizers will be
cleared again. "Test time" will show the duration of
on-the-fly calibration, and "Test ext." can trigger on-
the-fly calibration by transmitting a control code in
Modbus format via an interface. This, however, is
conditional on the fact that manual on-the-fly cali-
bration has been switched off (this is indicated by
the text ">OTFC start w. enter" in the first line).