Screen: 8.1.1.2 (Digital Output 1 – Parameters) - RMG EC 900 Operating Instructions Manual

Compact gas volume corrector
Table of Contents

Advertisement

..........................................................................................................................................................................................................
Settings:
see 6.3.0.0
see 5.1.4.0
see 8.1.1.2
see 8.1.2.2
Screen: 8.1.1.2 (digital output 1 – parameters)
DA1 src
DA1 type
DA1 sfac
DA1 pulse
DA1 ipp
DA1 HF
DA1 test
<OUTPUTS CU
Through the DA1 test parameter, you can set a number of pulses which will then have to be output-
ted. The number of pulses outputted will be shown in field DA1 act (screen 8.1.1.1).
"Dispat. LF CU" under DA1 type means that pulse output 1 is switched off. The value selected un-
der DA1 src is digitally transmitted to the CU 900 from where it is outputted via pulse output 1.
NOTE: It is possible that delays occur. As a result, pulse output 1 of the CU 900 can no longer be
used as digital output 3 of the EC 900.
Screen: 8.1.2.0 (digital output 2)
+Display values
+Parameters
<OUTPUTS CU
..........................................................................................................................................................................................................
Tot. chan. = Chan. Vo
VO chan.
= Encoder
Q mode
= flow m or flow v
DA1 src
= Flow or Flow bcond
DA1 type = Dispat. LF CU
DA2 src
= Flow or Flow bcond
DA2 type = Dispat. LF CU
Vm
Selection of the source for digital output 1
{Vm|Vb|Vo|Flow|Flow bcond}
Dispat. LF
Selection of the type of digital output 1
{Off|Tot. LF|Dispat. LF|Dispat. LF CU|Dispat. HF}
1.000000
Scaling factor for the type of pulse output
50 ms
Sel. of pulse duration for LF pulse output {10ms|25ms|
50ms|75ms|100ms|150ms|200ms|250ms|500ms}
50 ms
Sel. of the interpulse period for LF pulse output {10ms|25ms|
50ms|75ms|100ms|150ms|200ms|250ms|500ms}
0.1 ms
Selection {0.05 ms|0.1 ms|0.2 ms|0.5 ms|1.0 ms}
0
Test of output pulses (only if DA1 type = Tot. LF)
>
"OUTPUTS" book
Press Enter to go to screen 8.1.2.1
Press Enter to go to screen 8.1.2.2
>
"OUTPUTS" book
OPERATION
99