Compact gas volume corrector
Table of Contents

Advertisement

OPERATION
..........................................................................................................................................................................................................

Screen: TOT

+Vb
00123400.00 m3
+Vm
00005566.00 m3
+VO
00009870.00 m3
+VbD
00000000.00 m3
+VmD 00000000.00 m3
+VmL
00000321.00 m3
62
< TOT PTZ OPER.>

Screen: 1.1.0.0 (totalizer functions)

+On-the-fly calibr.
+Setting totalizers
+Totalizer mode
+Load limits
<TOT PTZ OPER.>

Screen: 1.1.1.0 (on-the-fly calibration)

>OTFC off with enter
>T Vb
>T Vm 0000.0000 m3
>Test time
Test ext.
<TOT PTZ OPER. >
Press Enter to start, stop, reset or switch off on-the-fly calibration. If on-the-fly calibration is to be
operated externally, manual on-the-fly calibration has to be switched off (see also page 53).

Screen: 1.1.2.0 (setting totalizers)

Set VmL
Set Vb
Set Vm
Set VO
<TOT PTZ OPER. >
In order to set the customer's VmL totalizer, it is sufficient to enter one of the user codes, whereas
one of the calibration codes can be used to set the Vm and VO totalizers. For the Vb totalizer, a
calibration code has to be entered and the calibration switch must have been opened.
..........................................................................................................................................................................................................
Press Enter to go to screen 1.1.0.0
Press Enter to go to screen 1.1.0.0
Press Enter to go to screen 1.1.0.0
Press Enter to go to screen 1.1.0.0
Press Enter to go to screen 1.1.0.0
Press Enter to go to screen 1.1.0.0
"TOT" book
Press Enter to go to screen 1.1.1.0
Press Enter to go to screen 1.1.2.0
Press Enter to go to screen 1.1.3.0
Press Enter to go to screen 1.1.4.0
"TOT" book
On-the-fly calibration
0000.0000 m3
On-the-fly calibration, volume at measurement conditions
On-the-fly calibration, volume at base conditions
0.00 s
Duration of on-the-fly calibration (s)
Off
Controlling on-the-fly calibration
{Off|OTFC start|OTFC stop|OTFC reset}
"TOT" book
00000000
Setting the customer's Vm (Vb) totalizer
00000000
Setting the Vb (Vn) totalizer
00000000
Setting the Vm (Vb) totalizer
00000000
Setting the VO totalizer
"TOT" book