Screen: 8.2.1.2 (Analogue Output 1 - Parameters); Screen: 8.2.2.0 (Analogue Output 2); Screen: 8.2.2.1 (Analogue Output 2 - Display Values); Screen: 8.2.2.2 (Analogue Output 2 - Parameters) - RMG EC 900 Operating Instructions Manual

Compact gas volume corrector
Table of Contents

Advertisement

OPERATION
..........................................................................................................................................................................................................

Screen: 8.2.1.2 (analogue output 1 - parameters)

A1 type
A1 src
A1 min
104
A1 max
A1 af
A1 cc
A1 cor
<OUTPUTS CU

Screen: 8.2.2.0 (analogue output 2)

+Display values
+Parameters
<OUTPUTS CU

Screen: 8.2.2.1 (analogue output 2 - display values)

>A2 phys
>A2 mA
<OUTPUTS CU

Screen: 8.2.2.2 (analogue output 2 - parameters)

A2 type
A2 src
A2 min
A2 max
A2 af
A2 cc
A2 cor
<OUTPUTS CU
..........................................................................................................................................................................................................
4-20mA
Selection of the type of analogue output 1
{Off|0-20mA|4-20mA|Cal.cur.on}
Qb
Sel. of the source for analogue output 1 {Pres-
sure|Temperat.|Conv. fact.|K coeff.|Qm|Qb|
Freq. chan1|Freq. chan2}
0.000
Analogue output 1, minimum range value
2000.000
Analogue output 1, maximum range value
1
Analogue output 1, averaging factor
12.000 mA
Analogue output 1, calibration current (mA)
0.000
Analogue output 1, correction factor
>
"OUTPUTS" book
Press Enter to go to screen 8.2.2.1
Press Enter to go to screen 8.2.2.2
>
"OUTPUTS" book
0.000
Analogue output 2, physical value
4.000 mA
Analogue output 2, current (mA)
>
"OUTPUTS" book
4-20mA
Selection of the type of analogue output 2
{Off|0-20mA|4-20mA|Cal.cur.on}
Qm
Sel. of the source for analogue output 2 {Pres-
sure|Temperat.|Conv. fact.|K coeff.|Qm|Qb|
Freq. chan1|Freq. chan2}
0.000
Analogue output 2, minimum range value
1000.000
Analogue output 2, maximum range value
1
Analogue output 2, averaging factor
12.000 mA
Analogue output 2, calibration current (mA)
0.000
Analogue output 2, correction factor
>
"OUTPUTS" book