OPERATION
..........................................................................................................................................................................................................

Screen: 7.1.0.0 (optical interface)

Op type
Op baud
Op bits
Op parity
Op stop
Op prot
94
Op fmt
Op test
Op addr
Op offset
Op Tout
Op btime
Op code
Op-M900crc
Op except
<COMM OUTPUTS CU >
Screen: 7.2.0.0 (COM1 interface)
MU type
MU baud
MU bits
MU parity
MU stop
MU prot
MU fmt
MU test
MU addr
MU offset
MU Tout
MU btime
MU code
MU M900crc
MU except
<COMM OUTPUTS CU >
..........................................................................................................................................................................................................
Slave
Selection of the type of optical interface MU {Off|Slave}
9600
Selection of the baud rate of the opt. interface MU
{1200|2400|4800|9600}
8
Selection of the data bits for the optical interface (fixed 8 bit)
Even
Sel. of the parity of the opt. interface MU {None|Even|Odd}
1
Selection of stop bits for the opt. interface MU {1|2}
Modb. RTU
Selection of the protocol for the opt. interface MU
{Modb. ASCII|Modb. RTU|M900}
4321
Selection of the Modbus format for the opt. interface MU
{4321|2143|1234}
Off
Selection of the Modbus test for the opt. interface MU
{Off|Test float|Test double|Test int|Test mode|Test long|
Test string|Test archive}
1
Modbus address of the opt. interface MU
Modbus offset for the opt. interface MU
0
5
Modbus timeout for the opt. interface MU
1
Modbus bit time for the opt. interface MU
No
Code required for access {No|Yes}
Yes
M900 protocol with CRC {No|Yes}
Yes
"Exception" message due to a wrong Modbus address {No|Yes}
"COMM" book
Modb. Intern
Selection of the type of COM1 interface MU
{Off|Modb. intern|Slave|Test rep.}
19200
Sel. of the baud rate for COM1 interface MU {9600|19200|38400}
Selection of data bits for COM1 interface MU {7|8}
8
Sel. of the parity for COM1 interface MU {None|Even|Odd}
None
Selection of stop bits for COM1 interface MU {1|2}
1
Modb. RTU
Selection of the protocol for COM2 interface MU
{Modb. ASCII|Modb. RTU|M900}
4321
Selection of the Modbus format for COM1 interface MU
{4321|2143|1234}
Off
Selection of the Modbus test for COM1 interface MU
{Off|Test float|Test double|Test int|Test mode|Test long|
Test string|Test archive}
1
Modbus address for COM1 interface MU
0
Modbus offset for COM1 interface MU
5
Modbus timeout for COM1 interface MU
1
Modbus bit time for COM1 interface MU
Yes
Code required for access {No|Yes}
Yes
M900 protocol with CRC {No|Yes}
Yes
"Exception" message due to a wrong Modbus address {No|Yes}
"COMM" book