Calibration Switch - RMG EC 900 Operating Instructions Manual

Compact gas volume corrector
Table of Contents

Advertisement

..........................................................................................................................................................................................................

Calibration switch

In order to make several changes (for example, to delete the legal metrological logbook), you have
not only to enter the M code, but also open the calibration switch. It is located at the bottom of the
main unit on the casing cover (below a plastic strip) and is protected by a seal for custody transfer
metering.
With opening the calibration switch also the calibration code 1 is automatically released. Opening
the calibration switch thus allows to change the parameters protected by calibration code or user
code.
..........................................................................................................................................................................................................
OPERATION
39