OPERATION
..........................................................................................................................................................................................................

Setting or resetting totalizers

50
. . . . . . . .
..........................................................................................................................................................................................................
1. In the "Totalizers" ("TOT") book, press Enter in any
line to reach the next chapter.
2. Press " " to reach the "Setting totalizers" line, and
then press Enter to move to the next screen.
3. Now use " " to select the totalizer to be set and
press Enter. You can set the Vb totalizer if you have
entered a calibration code (C1, C2 or C3) and set the
calibration switch to its "input" position (see figure
on page 39). To set the Vm and VO totalizers, it is
sufficient to use one of the calibration codes; and
one of the user codes for the customer's VmL total-
izer.
4. Use the " " or " " key to set the desired totalizer
reading digit by digit.
5. If you select "Totalizer mode" instead of "Setting
totalizers" under item 2, you will reach the menu
shown on the left. Press " " once and then Enter in
the "Reset" line and you will reach a selection option
where you can reset totalizers. Set the selection text
to "Totalizers" and press Enter. All totalizers will then
be set at 0. Afterwards, the selection text will auto-
matically switch back to "Off".