Signal input
Reed/Namur ................................................ Energy limited
Terminal X5
E3+, E3-
Terminal X6
E4+, E4-
Terminal X7
E5+, E5-
Terminal X8
E6+, E6-
Terminal X9
E7+, E7-
Terminal X10
E8+, E8-
Vo – Encoder input
Namur .......................................................... Energy limited
Terminal X11
Vo+, Vo-
Temperature input PT 1000
Reed/Namur/Wiegand ................................ Energy limited
Terminal X2
M+, M-
Terminal X3
V+, V-
Analogue circuit Iin1, 2 ............................... 0 - 20 mA, R
Terminal X12
+Iin1, -Iin1
Terminal X13
+Iin2, -Iin2
..........................................................................................................................................................................................................
Maximum values per circuit
U
= 10.6 V
o
I
= 12.5 mA
o
Characteristic line: linear
C
and L
are negligible
i
i
Maximum values
U
= 10.6 V
o
I
= 15 mA
o
Characteristic line: linear
C
and L
are negligible
i
i
Maximum values
U
= 10.5 V
o
I
= 11 mA
o
Characteristic line: linear
C
= 21 nF, L
is negligible
i
i
< 120 Ohm
i
U
<= 30 V
i
I
<= 110 mA
i
P
<= 1.2 W
i
C
= 21 nF
i