Screen: 4.1.3.0 (Monthly Archive) - RMG EC 900 Operating Instructions Manual

Compact gas volume corrector
Table of Contents

Advertisement

..........................................................................................................................................................................................................

Screen: 4.1.3.0 (monthly archive)

+Monthly archive
Read rec.
Level
>Run.No
>TS07:00:00 27.08.13
>Cur level
>Opt read
>COM1 read
ST00:00:00 01.11.07
AG3
< TARIFF FLOW TYPE >
Screen: 4.1.3.1 (monthly archive - entries)
Monthly archive
Index/CRC:
Time stamp:
Running No.:
Last index no.:
Monthly archive
VO
VO status:
Vb
Vb status:
Vm
Monthly archive
Vm status:
VbD
VbD status:
VmD
VmD status:
Monthly archive
p
p status:
t
t status:
K
..........................................................................................................................................................................................................
0
24
51
5
0
5
AG3
2/CBAB
06:00:00 01.11.13
14
2
06:00:00 01.11.13
00009870 m3
0
00123400 m3
0
00005566 m3
06:00:00 01.11.13
0
00000000 m3
1
00000000 m3
1
06:00:00 01.11.13
0.999
bara
0
24.04
°C
0
1.00066
Press Enter to go to screen 4.1.3.1
Input of the read record No. xxxx (Modbus Omni)
Display of the level (max. 24 entries). Reset only by deleting
the archive.
Last running number
Last time stamp
Current write index
Read index, opt. interface
Read index, COM1 interface
Time as a search criterion for archives
Name of archive group 3
"TARIFF" book
Headline: Monthly archive
Memory position of the entry / checksum of the entry
Time stamp of the entry
Time and date
Running number of the displayed entry
Memory position of the last entry
Headline: Monthly archive
Time stamp: Time and date
Totalizer reading original totalizer
Totalizer status: (0: running, 1: stopped)
Totalizer reading volume at base conditions
Totalizer status: (0: running, 1: stopped)
Totalizer reading volume at measurement conditions
Headline: Monthly archive
Time stamp: Time and date
Totalizer status: (0: running, 1: stopped)
Totalizer reading disturbance quantity volume at base cond.
Totalizer status: (0: running, 1: stopped)
Totalizer reading disturbance quantity volume at meas. cond.
Totalizer status: (0: running, 1: stopped)
Headline: Monthly archive
Time stamp: Time and date
Mean value of pressure
Meas. val. status (0: ok, 2: def. value, 3: fixed value, 4: holding value)
Mean value of temperature
Meas. val. status (0: ok, 2: def. value, 3: fixed value, 4: holding value)
Mean value of compressibility factor
OPERATION
77

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents