Screen: 2.4.0.0 (Components For K Coefficient Calculation Using Aga 8-92Dc); Screen: 2.4.1.0 (Co 2 Source) - RMG EC 900 Operating Instructions Manual

Compact gas volume corrector
Table of Contents

Advertisement

OPERATION
..........................................................................................................................................................................................................

Screen: 2.4.0.0 (components for K coefficient calculation using AGA 8-92DC)

Oper.Mode: DSfG_Modbus
+CO2:
+H2:
+N2:
+Methane:
+Ethane:
68
+Propane:
+N-butane:
+I-butane:
+N-pentane: 0.0000 Mol%
+I-pentane:
+NeoPentan: 0.0000 Mol%
+Hexan/C6+: 0.0000 Mol%
+Heptane/0: 0.0000 Mol%
+Octane/0:
+Nonane/0: 0.0000 Mol%
+Decane/0: 0.0000 Mol%
+H2S:
+Water:
+Helium:
+O2:
+CO:
+Ethene:
+Propene:
+Argon:
<PTZ OPER. TARIFF>
Important note
The following conditions must be fulfilled to use the input values for the components with the K
coefficient calculation method AGA 8-92DC:
K coefficient calculation method Kmode = AGA8_92DC is selected.
Components mode Oper.Mode = Set value is selected.
The sum of the components must be equal to 100% (± 0.01).
Screen: 2.4.1.0 (CO
Default:
CO2:
<PTZ OPER. TARIFF>
The screens 2.4.2.0 (H
2.4.1.0 and are therefore not listet in particular.
..........................................................................................................................................................................................................
Source of gas components {Off|DSfG_Modbus|Set value}
0.5000 Mol%
Value for calculation, press Enter to go to screen 2.4.1.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.2.0
6.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.3.0
84.5000 Mol%
Value for calculation, press Enter to go to screen 2.4.4.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.5.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.6.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.7.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.8.0
Value for calculation, press Enter to go to screen 2.4.9.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.10.0
Value for calculation, press Enter to go to screen 2.4.11.0
Value for calculation, press Enter to go to screen 2.4.12.0
Value for calculation, press Enter to go to screen 2.4.13.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.14.0
Value for calculation, press Enter to go to screen 2.4.15.0
Value for calculation, press Enter to go to screen 2.4.16.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.17.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.18.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.19.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.20.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.21.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.22.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.23.0
0.0000 Mol%
Value for calculation, press Enter to go to screen 2.4.24.0
"PTZ" book
source)
2
0.5000 Mol%
CO
default value
2
0.0000 Mol%
CO
bus value
2
"PTZ" book
source) to 2.4.24.0 (argon source) have the same structure as the screen
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents