AudioCodes Mediant 800 User Manual page 1468

Gateways & session border controllers
Hide thumbs Also See for Mediant 800:
Table of Contents

Advertisement

CHAPTER 72    Configuration Parameters Reference
[AMDMaxPostGreetingSilenceTime]
[AMDTimeout]
'AMD Beep Detection Mode'
configure voip > sip-
definition settings > amd-
beep-detection
[AMDBeepDetectionMode]
'Answer Machine Detector Beep
Detection Timeout'
configure voip > media
ipmedia > amd-beep-
detection-timeout
[AMDBeepDetectionTimeout]
'Answer Machine Detector Beep
Detection Sensitivity'
configure voip > media
ipmedia > amd-beep-
detection-sensitivity
[AMDBeepDetectionSensitivity]
early-amd
[EnableEarlyAMD]
Parameter
Mediant 800 Gateway & E-SBC | User's Manual
Description
Global parameter that defines the maximum duration of
silence from after the greeting time is over, configured
by [AMDMaxGreetingTime], until the device's AMD
decision. You can also configure this feature per
specific calls, using IP Profiles (IpProfile_
AMDMaxPostSilenceGreetingTime). For a detailed
description of the parameter and for configuring this
feature in the IP Profiles table, see
Profiles.
Note: If this feature is configured for a specific IP
Profile, the settings of this global parameter is ignored
for calls associated with the IP Profile.
Defines the timeout (in msec) between receiving
Connect messages from the Tel side and sending
AMD results.
The valid range is 1 to 30,000. The default is 2,000
(i.e., 2 seconds).
Defines the AMD beep detection mode. This mode
detects the beeps played at the end of an answering
machine message, by using the X-Detect header
extension. The device sends a SIP INFO message
containing the field values 'Type=AMD' and
'SubType=Beep'. This feature allows users of certain
third-party, Application servers to leave a voice
message after an answering machine plays the "beep".
[0] Disabled (default)
[1] Start After AMD
[2] Start Immediately
Defines the AMD beep detection timeout (i.e., the
duration that the beep detector functions from when
detection is initiated). This is used for detecting beeps
at the end of an answering machine message.
The valid value is in units of 100 milliseconds, from 0
to 1638. The default is 200 (i.e., 20 seconds).
Defines the AMD beep detection sensitivity for
detecting beeps at the end of an answering machine
message.
The valid value is 0 to 3, where 0 (default) is the least
sensitive.
Enables AMD detection to be activated upon receipt of
an ISDN Alerting or Connect message.
[0] = (Default) Disable - AMD is activated upon
receipt of ISDN Connect message.
[1] = Enable - AMD is activated upon receipt of
ISDN Alerting message.
- 1428 -
Configuring IP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-sbc

Table of Contents