Technical Data
4
SPC6000
36
Vanderbilt
Electronic Outputs
Firmware
Door capacity
Number of card reader
Radio module
Verification
Video
Audio
Field bus 1)
Number of field devices 2)
Connectable field devices
Interfaces
Tamper contact
Power supply
Mains voltage
Mains fuse
Power consumption
Operating current
Quiescent current
Installation & Configuration Manual
SP6320\6330 — 5 outputs:
2 internal/external bells
3 programmable. Maximum 400 mA resistive
switching current per output, supplied by auxiliary
output.
SPC6350 — 8 outputs. Maximum 400mA resistive
switching current per output
5 standard power outputs
3 supervised outputs
V3.x
Max. 64 entry doors or 32 entry/exit doors
Max. 64
Optional (SPCW110)
32 verification zones with max. 4 IP-cameras and 32 audio
devices.
Up to 16 pre / 16 post event images (by JPEG resolution
320 x 240, max. 1 frame / sec.)
Up to 60 sec. pre / 60 sec. post audio recording
X-BUS on RS-485 (307 kb/s)
Max. 128 (32 keypads, 32 door-expanders, 64 input/output
expanders)
Keypads: SPCK42x, SPCK62x
Door expanders: SPCA210, SPCP43x
Expanders with I/O: SPCE65x, SPCE45x, SPCP33x,
SPCP35x, SPCE110, SPCE120, SPCV32x
2 X-BUS (2 spurs or 1 loop),
2 RS232
1 USB (PC connection),
1 SPC Fast Programmer,
SPC63xx: Additionally 1 Ethernet (RJ45)
SPC6330: Front spring tamper, 2 auxiliary tamper
contact inputs
SPC6350: Front/back tamper switch
Type A (per EN50131-1)
230 V AC, + 10%/ -15%, 50 Hz
SPC6330 : 250 mA T (replaceable part on mains
terminal block)
SPC6350 : 800mA T (replaceable part on mains
terminal block)
SPC6330: Max. 200 mA at 230 V AC
SPC6350: Max. 500mA at 230 V AC
SPC6330: Max. 200 mA at 12 V DC
SPC6350: Max. 210 mA at 12 V DC
SPC63xx Controller: Max. 170 mA at 12 V DC (195 mA with
PSTN, 300 mA with GSM, 325 mA with PSTN & GSM)
A6V10276959