Vanderbilt SPC42 Series Installation & Configuration Manual page 232

Hide thumbs Also See for SPC42 Series:
Table of Contents

Advertisement

Engineer programming via the browser
17
Configuration
232
Vanderbilt
Timer
Description
Mains Delay
The time after a mains fault has been detected before an alert
is activated by the system. (0 – 60 minutes)
MAINS SIG DELAY
Engineer
Engineer Access
The timer for the Engineer access starts as soon as the user
enables the Engineer Access. (0 – 999 minutes. '0' indicates
ENGINEER ACCESS
no time limitation for system access)
Engineer auto log out
Duration of inactivity after which the engineer will be
automatically locked out
ENG AUTO LOG OUT
Keypad
Keypad Timeout
The number of seconds that an RKD will wait for key entry
before it leaves the current menu. (10 – 300 seconds)
KEYPAD TIMEOUT
Keypad Language
The duration a keypad will wait in idle before switching
language to default ( 0 - 9999 seconds; 0 = never).
KEYPAD LANGUAGE
Fire
Fire Pre-alarm
Number of seconds to wait before reporting fire alarm for
zones with 'Fire pre-alarm' attribute set. (1 – 999 seconds)
FIRE PRE-ALARM
See Editing a Zone [➙ 237].
Fire recognition
Extra time to wait before reporting file alarm for zones with
'Fire pre-alarm' and 'Fire Recognition' attributes set. (1 – 999
FIRE RECOGNITION
seconds). See Editing a Zone [➙ 237].
PIN
PIN Valid
Period for which pin is valid in days ( 1 - 330 )
PIN VALID
PIN Changes Limit
Number of changes within a valid period ( 1 - 50 )
PIN CHANGES LIMIT
PIN Warning
Time before PIN expiry after which a warning will be
displayed
PIN WARN
( 1 - 14 )
General Settings
RF Output Time
The time that the RF output will remain active on the system.
(0 – 999 seconds)
RF OUTPUT
Time Sync Limit
Time limit within which no event will be reported.
(0 – 999 secs) Time synchronization only takes place if
TIME SYNC LIMIT
system time and update time are outside this limit.
Link Timeout
Timeout for Ethernet link fault (0 = Disabled) ( 0 - 250 )
LINK TIMEOUT
Camera Offline
Time for camera to go offline ( 10 - 9999 )
CAMERA OFFLINE
Tech. delay
Number of seconds to delay triggering of tech. zones with
tech. delay attribute. (0 – 9999 seconds)
TECH. DELAY
Frequent
This attribute only applies to Remote Maintenance. The
number of hours a zone must open within if the zone is
FREQUENT
programmed with the Frequent use attribute. (1 – 9999 hours)
Duress silent
Time when duress will remain silent and not restorable from
keypad (0 - 999).
Holdup/panic silent
Number of minutes that a holdup/panic will remain silent and
cannot be restored from the keypad (0 - 999).
Installation & Configuration Manual
Default
0 min.
0 min.
0 mins.
30 sec.
10 secs
30 sec.
120 sec.
30 days
5
5 days
0 sec.
0 sec.
0 secs
10 secs
0 sec.
336 hours (2
weeks)
0 Minutes
0 Minutes
A6V10276959
01.05.2016