17.9.3.2.1
Vanderbilt
To configure a WPA from the browser:
Select Full Engineer mode and select the following options Configuration >
Hardware > Wireless > WPA.
The following items can be checked or configured from this page:
Battery Status
The panel receives the battery status from the WPA in every frame. The battery
status can be either OK or Low.
Battery monitoring requires a WPA fitted with the PCB revision E-PC138612 or
later.
Supervise Status
The Supervise status can be any of the following:
Fault
The panel has not received a supervision message from the WPA in the
period configured in the Wireless Settings page.
Disabled
Supervision is not configured.
OK
Supervision is transmitting normally.
Test Status
The Test Status can be any of the following:
Overdue
The WPA has not been tested in the period configured in the Wireless
Settings page.
Disabled
Supervision is not configured.
OK
The WPA test is ok.
1. Click on the Edit button to edit the WPA configuration.
2. Click on the Delete button to delete a WPA from the system.
Adding a WPA
To add a WPA to the system:
Click the Add button in the main WPA Configuration and Status page.
 The Configure WPA page is displayed for the new WPA.