Engineer programming via the browser
17
Configuration
17.9.5.2.3
17.9.5.2.4
240
Vanderbilt
Configure the operation of particular zones for both Partset A and Partset B modes
as detailed below:
Partset Enable
Partset Timed:
Partset Access:
Partset Exit/Entry:
Partset Local:
No Bells
Linked Areas
This section enables you to link areas for setting and unsetting purposes:
Fullset
Fullset All
Prevent Fullset
Prevent Fullset All
Unset
Unset All
Prevent Unset
Prevent Unset All
Authorise Setting
Linked Areas
Schedule
Configure scheduling with the following settings:
Calendar
Unset
Fullset
Installation & Configuration Manual
Enable PartSet for A and B operation as required.
Tick the relevant checkbox (Partset A or B) to apply the exit
timer to the Partset A or B mode.
Tick the relevant checkbox to change access zones into
entry/exit type zones for either Partset A or B operation. This
feature is useful for a domestic installation where a Passive
Infrared (PIR) sensor is located in the hallway. If the user
partsets the system at night and returns downstairs during the
night, he/she may unintentionally activate the PIR sensor in
the hallway and trigger the alarm. By setting the partset
access option, the buzzer will sound for the entry time period
when the PIR sensor is activated thereby warning the user
that the alarm will activate if no action is taken.
Tick the relevant checkbox to change the behaviour of
entry/exit zones to alarm zones when in Partset A or B mode.
This feature is useful for a domestic installation when the
system has been set in partset mode. If the user partsets the
system at night he/she may wish the alarm to activate
immediately if the front or back door is opened during the
night.
Tick the relevant checkbox to restrict the reporting of alarms
in Partset Mode to local reporting only (No remote reporting).
If ticked, no bells will be activated for partset A or B.
Fullset this area when all linked areas are Fullset.
Fullset all areas when this area is Fullset.
Prevent this area from Fullset if all linked areas are Fullset.
Prevent linked areas from Fullset if this area is not Fullset.
Unset this area when all linked areas are Unset.
Unset all areas when this area is Unset.
Prevent this area from Unset if any linked areas are Fullset.
Prevent linked areas from Unset if this area is Fullset.
Enable authorised setting for linked areas. Refer
Authorised Setting of the Blocking Lock.
Click on the areas that you wish to link to this area.
Select a calendar to control scheduling.
Select if area should automatically Unset as
per the time specified in the selected
calendar.
Select this option to Fullset the area as per
A6V10276959