Name
Area
(Web and SPC Pro only)
Door Position (Web)
DPS End Of Line (keypads)
Door Position EOL (SPC Pro)
DPS Normal Open
Door Release (Web)
DRS END OF LINE (Keypads)
Door Position EOL (SPC Pro)
DRS Normal Open
No DRS
(Web and SPC Pro only)
Reader Location (Entry/Exit)
(Web and SPC Pro only)
Reader formats (Web)
READER INFO (Keypads)
Each free zone number can be assigned to the zones but the assignment is not
fixed. If the number '9' is assigned to a zone, the zone and an input expander with
the address '1' is connected to the X-Bus (which is using the zone numbers 9-16).
The assigned zone from the two door controller will be moved to the next free
zone number. Configuration will be adapted accordingly.
Door attributes
If no attribute is activated, a valid card can be used.
Attribute
Void
Door Group
Card and PIN
PIN Only
PIN Code or Card
PIN to Exit
PIN to Set/Unset
Unset outside (Browser)
Unset on Entry Reader (SPCPro)
Installation & Configuration Manual
Engineer programming via the browser
Description
The area the zone and the card reader are assigned to.
(If the card reader is used for setting & unsetting, this
area will be set / unset).
The resistor used with the door position sensor. Choose
the used resistor value / combination.
Select if the door release switch is to be a normally open
or normally closed input.
The resistor used with the door release switch. Choose
the used resistor value / combination.
Select if the door release switch is a normally open input
or not.
Select to ignore DRS.
If a DC2 is used on the door, this option MUST be
selected. If not selected, the door will open.
Select the location of the entry and exit readers.
Displays format of last card used with each configured
reader. (not available in SPC Pro)
Description
The card is temporarily blocked.
Used when multiple doors are assigned to the same
area and/or anti passback, custodian, or interlock
functionality is required.
Card and PIN are required to gain entry.
PIN is required. No card will be accepted.
PIN or card are required to gain entry
PIN is required on exit reader. Door with entry and
exit reader is required.
PIN is required to set and unset the linked area. The
card has to be presented before the PIN is entered.
Panel/area will unset, when card is presented at entry
reader.
17