Engineer programming via the browser
Description
two activations may come from the same device if
the activations differ in type, i.e. alarm / tamper.
- 1 Alarm activation followed by an ATS[1] Fault
within 30 minutes (default).
- ATS fault followed by a tamper or alarm condition
within 30 minutes (default).
If the 30 minutes expires and the zone is restored to
its normal physical state, then the zone's alerts will
be restored if a level 2 user can restore this alert. In
this case, the zone will accept a new alert condition
which will cause a new activation.
Alternatively, if the zone has not been restored to its
normal physical state then that zone will be inhibited
if that zone is allowed to be inhibited.
If an alert (ATS) reoccurs after the 30 minute window
(default), then the 30 minute timer will restart.
The EN50131-9 confirmation option is automatically
set whenever the Standards -> Region option is set
to Spain.
VDS
This will enforce compliance with the VDS standard.
If enabled, the setting status of the system (Fullset /
Partset / Unset) is permanently displayed in the bottom
line of the keypad display. If unchecked the setting status
will disappear from the keypad display after 7 seconds.
If enabled, open zones will display on keypad in Unset
mode.
If enabled, the ARC message will be displayed for 30
seconds after Unset, if confirmed alarm has been
reported..
ARC message in line 1 of display (16 chars).
ARC message in line 2 of display (16 chars).
If enabled, offline cameras will be displayed on the
keypad in Unset mode.
Select the language displayed in idle state.
System Language: Language in which menus and
texts on the keypads, the web interface and the event
log will be displayed.
Last Used: Last used language is displayed in idle
state.
Enter the number of digits for user PINs (max. 8 digits).
Increasing the number of digits will add the relevant
number of zeros to the front of an existing PIN, e.g. an
existing user PIN of 2134 (4 digits) will change to
00002134 if the PIN digits is set to 8. If you decrease the
number of PIN digits, existing PINs will have their leading
digits removed, e.g. an existing user PIN of 00002134 (8
digits) will change to 02134 if the PIN digits is set to 5.
Note: This option cannot be changed if an SPC Manager
PIN digit mode is set. Refer to page [➙ 303]
Note: To comply with INCERT approvals, the user's PIN
code must contain more than 4 digits.
17
Configuration
227
A6V10276959
01.05.2016