Vanderbilt SPC42 Series Installation & Configuration Manual page 228

Hide thumbs Also See for SPC42 Series:
Table of Contents

Advertisement

Engineer programming via the browser
17
Configuration
228
Vanderbilt
Restriction
System Option
PACE and PIN
User Duress
PIN Policy
Door
Reset Cards
Ignore site code
Card Formats
Web and
Door Mode Set
SPC Pro
Only
Web and
Door Mode Unset Select the required user identification to unlock door
SPC Pro
Only
Engineer
Engineer Restore (Impact only if Region "UK" is chosen): If this option is
!
Engineer Exit
Installation & Configuration Manual
Description
If enabled, both PACE and PIN are required.
Select one of the following Duress options to activate this
function on the system.
PIN +1(system reserves the PIN before and after the
user PIN for duress.
PIN + 2 (system reserves two PINs before and after
the user PIN for duress.
Duress must be enabled for individual users. See section
on Adding/Editing a User.
Click on the Edit button to select options for PIN usage.
Periodic changes required – enforces scheduled
changes to the user's PIN. The period is defined in
the PIN Valid field of Timers. See Timers [➙ 230].
Warn if changes required – generates a user alert if
the user's PIN is about to expire, or has expired. The
warning period is defined in the PIN Warning field of
Timers. See Timers [➙ 230].
User selects the last digit – enables the user to select
the last digit of their pin. The preceding digits are
automatically generated by the system.
User selects the 2 digits - enables the user to select
the last two digits of their PIN. The preceding digits
are automatically generated by the system.
Limit Changes – limits the number of changes
possible within a valid PIN period. This value is
defined in the PIN Changes Limit field of Timers. See
Timers [➙ 230]
Secure PIN - If enabled the PIN will be automatically
generated by the panel.
If enabled, access cards passback state will be reset
every day at midnight.
If enabled, the access system will ignore site codes. By
ignoring the site code, you only add the card number and
increase the card users on the system from 100 to 2,500.
Click on the Edit button to select the card formats that will
be allowed on this panel.
Refer to the Appendix in the SPC Installation &
Configuration Guide for details of currently supported
card readers and card formats.
Note: Selecting Wiegand enables all Wiegand card
formats.
Select the required user identification to unlock door
when area is set. Options are Default, Card and PIN,
Card Or PIN.
when area is unset. Options are Default, Card and PIN,
Card Or PIN.
enabled, then the engineer has to restore the confirmed
alarms. This option works together with the function
"Confirmation".
If enabled, the engineer is allowed to leave Full Engineer
mode with alerts active.
A6V10276959
01.05.2016