Vanderbilt SPC42 Series Installation & Configuration Manual page 188

Hide thumbs Also See for SPC42 Series:
Table of Contents

Advertisement

Engineer programming via the browser
17
Users
188
Vanderbilt
Right
User Profile
Type Default
Isolate
Standard*
Manager
User Rights - System
Web Access
Standard*
Manager
View Log
Standard
Manager
Users
Manager
SMS
Standard*
Manager
Set Date
Standard
Manager
Change PIN
Standard
Manager
View
Standard
Video/Video in
Manager
Browser
Chime
Standard
Manager
Engineer
Manager
Upgrade
Manager
User Rights - Control
Outputs
Standard
Manager
X-10
Standard
Manager
Access Control
Door Control
Standard*
Manager
Access Control
Installation & Configuration Manual
Description
on the keypad each time the system is being set to
remind the user to attend to that zone.
Isolating a zone deactivates that zone until such time
as the zone is de-isolated. All zone types on the
controller can be isolated.
Use of this feature to deactivate faulty or open zones
should be considered carefully; once a zone is isolated,
it is ignored by the system and could be overlooked
when setting the system in the future, compromising
the security of the premises.
User can access panel through web browser.
This menu option displays the most recent event on the
keypad display. The event log [➙ 149] details the time
and date of each logged event.
User can create and edit other users on the panel but
with only the same or less rights than this user.
This feature allows users to set up the SMS messaging
service if a modem is installed on the system.
Use this menu option to program the time and date on
the system [➙ 157].
Ensure the time and date information is accurate; these
fields are presented in the event log when reporting
system events.
This menu option allows users to change their user
PINS [➙ 150].
Note: To comply with INCERT approvals, the user's
PIN code must contain more than 4 digits.
User can view video images via the web browser.
Note: The Web Access right must also be enabled for
this function.
All zones that have the CHIME attribute set generate a
short burst of audible tone on the keypad buzzer when
they are opened (while the system is unset).
This menu option allows for enabling or disabling of the
chime feature on all zones.
This option allows users to grant access to engineer
programming.
For Swiss CAT 1 and CAT 2 regional requirements,
when Engineer Access is granted, all areas must be
unset otherwise the engineer will be denied access.
User can grant manufacturer access to panel to
perform firmware upgrade.
User can activate/deactivate configured outputs
(mapping gates). See Editing an Ouput [➙ 197].
User can activate/deactivate configured X-10 devices.
Note: X-10 is in maintenance. The functionality remains
in the system for backward compatibility.
User can lock/unlock doors.
A6V10276959
01.05.2016

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents