Engineer programming via the browser
17
SPC Home
166
Vanderbilt
 All the configured and operational cameras (up to the maximum of four) are
displayed in the Video Cameras page. Only two cameras are available in
the following example.
The images are automatically refreshed as per the interval settings for the camera.
(See Configuring Video [➙ 257])
Click on the Pause Refresh button to retain the current image on the screen and
pause refreshing. Click on the Resume Refresh button to enable the panel to
resume refreshing the images.
Note: Ensure that a resolution of 320 x 240 is selected for the cameras that will be
displayed in the browser otherwise images may not be displayed correctly. The
higher resolution of 640 x 480 can be used for operation with SPC Pro and SPC
Com.
Video Fault Reporting
A video fault report is displayed above the camera image. The following table lists
the possible messages:
Message
Description
OK
The camera is behaving normally
Timeout
Camera connection timed out.
Socket Invalid
Internal socket handling error
Image too small
Received image too small
Buffer too small
Received image is too large. Lower the resolution in the Camera
configuration.
Format incorrect
Invalid format received.
Abort
TCP connection disconnected
Internal
Alarm panel has insufficient memory to complete the request.
Bad request
A badly formed request was sent to the camera. Check your
camera configuration settings.
Client error
The camera returned a client error. Check your camera
configuration.
Authorization error
User name and/or password are incorrect
Unknown
An unknown error was returned. The camera may be an
unsupported model.