RF Output
Modem 1 Line Fault
Modem 1 Failure
Modem 2 Line Fault
Modem 2 Failure
Battery Low
Entry Status
Warning Status
Ready to Set
Setting ACK
(SPC Pro — Setting Complete)
Fullset Done
(SPC Pro — Setting Success)
Blockschloss 1
Blockschloss 2
Lock Element
Unlock Element
Code Tamper
Trouble
Ethernet Link
Network Fault
Glass Reset
Confirmed holdup
Full Engineer
Vanderbilt
This output activates when a Fob or WPA button is pressed.
This output activates when there is a line fault on the primary modem..
This output activates when the primary modem fails.
This output activates when there is a line fault on the secondary modem.
This output activates when the secondary modem fails.
This output activates when the battery is low,
This output activates if an 'All Okay' entry procedure is implemented and there is no
alarm generated i.e. the 'All Okay' button is pressed within the configured time after the
user code is entered.
This output activates if an 'All Okay' entry procedure is implemented and a silent alarm
generated i.e. the 'All Okay' button is not pressed within the configured time after the
user code is entered.
This output activates when an area is ready to set.
This output signals the setting status. The output toggles for 3 seconds to signal that
the setting has failed. The output remains on for 3 seconds if setting is successful.
This output activates for 3 seconds to signal that the system has been fullest.
Used for normal Blockschloss devices.
When all zones in an area are closed, and there are no pending faults, the
'Blockschloss 1' output is activated. If the lock on the Blockschloss is closed, a
'Keyarm' input is activated, the relevant area is set and the 'Setting Ack' output is
activated for 3 seconds to signal that the setting was successful. 'Blockschloss 1' is not
deactivated.
If the Blockschloss is unlocked, the Blockschloss device deactivates the Keyarm input
to the unset state (closed) and the area is unset. 'Blockschloss 1' is then deactivated.
Used for Blockschloss device type - Bosch Blockschloss, Sigmalock Plus, E4.03.
When all zones in an area are closed, and there are no pending faults, the
'Blockschloss 2' output is activated. If the lock on the Blockschloss is closed, a
'Keyarm' input is activated, the relevant area is set and the 'Setting Ack' output is
activated for 3 seconds to signal that the setting was successful. 'Blockschloss 2' is
then deactivated.
If the Blockschloss is unlocked, the Keyarm zone is switched to unset (closed) and the
area is unset. 'Blockschloss 2' is activated (if area is ready to set).
Activates if the Lock Element is in the 'locked' position.
Activates if the Lock Element is in the 'unlocked' position.
Activates if there is a code tamper in the area. Clears when state is reset.
Activates if any zone is in trouble state.
Activates if there is a fault on the Ethernet link.
Activates if there is an EDP communications fault.
Used to switch on the power for the glassbreak interface module and to remove power
in order to reset the device. The output is reset if a user enters their code, the zone is
not in the closed state, and the bells deactivated.
Activates in the following scenarios for PD6662 compliance:
two hold-up zone activations more than two minutes apart
a hold-up zone and a panic zone activation more than two minutes apart
If a hold-up zone and a tamper zone or a panic zone and a tamper zone activation
occurs within the two minute period
Activates if an engineer is on site and the system is in full engineer mode.
This output type can only indicate system wide events (no area specific events).
*