Vanderbilt SPC42 Series Installation & Configuration Manual page 265

Hide thumbs Also See for SPC42 Series:
Table of Contents

Advertisement

17.10.1.3.3
17.10.1.3.4
Vanderbilt
SMS system options
Once a modem is installed and the SMS feature enabled, for SMS operations the
SPC system must apply the SMS Authentication.
1. Select Configuration > System > System Options.
2. Select the desired option from the drop-down menu SMS Authentication:
PIN Only: This is a valid user code. See page [➙ 105].
Caller ID Only: This is the phone number (including 3-digit country prefix code)
as configured for User SMS Control. Only when this option is selected will the
SMS Control be available for configuration by the user.
PIN and Caller ID
SMS PIN Code Only: This is a valid PIN code configured for the user which
different from the user's login code. See page. Only when this option is
selected will the SMS Controls be available for configuration by the user.
SMS PIN Code & Caller ID
SMS commands
Once the SMS setup and configuration is complete, SMS features may be
activated. Commands, depending on SMS configuration are sent using a code or
caller ID. The type of code depends on what is set for SMS Authentication. For
The table below provides all available SMS commands. Subsequent action and
response are also provided.
SMS Commands are sent as texts to the phone number of the SIM card on the
controller.
For commands using code, the format of the text is the code followed by either a
space or a full stop. Where **** is the code and "command" is the command:
****.command or **** command.
For example, the command "HELP" is this text: **** HELP or ****.HELP.
COMMANDS (**** = code)
Using Code
Using Caller
ID
**** HELP
HELP
****.HELP
**** FSET
FSET
(FULLSET)
****.FSET
****ASET (PARTSET
A)
****.ASET
**** BSET
(PARTSET B)
****.BSET
**** USET
USET
****.USET
**** SSTA (STATUS)
SSTA
****.SSTA
**** XA1.ON
Installation & Configuration Manual
Engineer programming via the browser
Configuring Communications
Action
All available commands
displayed
Fullset Alarm
Allows Partset A of alarm by
SMS
Unset Alarm
Status displayed
Where X10 device is
identified as "A1", it is
17
Response
All available
commands
Time/date of system
set. If applicable,
responds with open
zones/forceset zones
System Unset
Status of system and
applicable areas
Status of "A1"
265
A6V10276959
01.05.2016

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents