Vanderbilt SPC42 Series Installation & Configuration Manual page 17

Hide thumbs Also See for SPC42 Series:
Table of Contents

Advertisement

Vanderbilt
EN50131 Requirement
How indications are made inaccessible to
level 1 users when level 2, 3 or 4 user is no
longer accessing the information (see 8.5.1)
Masking/reduction of range
signals/messages processed as "fault" or
"masking" events (see 8.4.1, 8.5.1 and Table
11);
Prioritization of signal and message
processing and indications (see 8.4.1.2,
8.5.3);
Minimum number of variations of PIN codes,
logical keys, biometric keys and/or
mechanical keys for each user (see 8.3);
Method of time-limiting internal WD for level
3 access without level 2 authorization (see
8.3.1);
Number and details of disallowed PIN codes
(see 8.3.2.2.1);
Details of any biometric authorization
methods used (see 8.3.2.2.3);
Method used to determine the number of
combinations of PIN codes, logical keys,
biometric keys and/or mechanical keys (see
11.6);
Number of invalid code entries before user
interface is disabled (see 8.3.2.4);
Details of means for temporary authorization
for user access (see 8.3.2);
if automatic setting at pre-determined times
provided, details of pre-setting indication and
any automatic over-ride of prevention of set
(see 8.3.3, 8.3.3.1);
Details of conditions provided for the set
state (see 8.3.3.4);
Notification of output signals or messages
provided (see 8.6);
Installation & Configuration Manual
Directives and standards
EU directives
SPC Installation & Configuration Manual
Keypad user interface [➙ 90]
Standard keypad settings [➙ 121]
Comfort keypad settings [➙ 122]
Configuring an Indicator Expander [➙ 206]
System Options [➙ 222]
Wiring the zone inputs [➙ 83]
SIA Codes [➙ 337]
PIR masking is always reported as a zone
masked event (SIA - ZM). Additionally, anti-
mask can cause an alarm, tamper, trouble
or no additional action depending on
configuration
Current defaults of PIR addition effect:
Ireland
Unset - None
Set - Alarm
UK, Europe, Sweden, Swiss, Belgium
Unset - Tamper
Set - Alarm
Standard keypad display [➙ 92]
Comfort keypad display [➙ 95]
User PIN combinations [➙ 344]
Not supported - Engineer cannot access
system without permission.
Automatic inhibits [➙ 345]
Not applicable
User PIN combinations [➙ 344]
Access PINs [➙ 345]
User Menus – Grant Access
Areas – Setting/Unsetting [➙ 243]
Setting and unsetting the system
Standard keypad configuration [➙ 121]
Comfort keypad configuration [➙ 122]
Outputs [➙ 198]
Zone types [➙ 347]
Outputs [➙ 198]
Areas – setting/unsetting [➙ 243]
User rights [➙ 187]
3
17
A6V10276959
01.05.2016

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents