Vanderbilt SPC42 Series Installation & Configuration Manual page 301

Hide thumbs Also See for SPC42 Series:
Table of Contents

Advertisement

17.10.3.2.4
Vanderbilt
Network
Report IP Network Polling Up/Down events.
Areas
Select specific areas to which above events apply.
Editing EDP settings
1. Select Communications > Reporting > EDP > Settings.
 The following window will be displayed.
2. Configure the fields as described in the table below.
Enable
Tick this checkbox to enable EDP operation on the system.
EDP Panel ID
Enter a numeric identifier that is used by the EDP Receiver to identify the
panel uniquely.
Panel Port
Select the IP port for receiving IP packets. Default is 50000.
Packet Size Limit
Enter the maximum number of bytes in an EDP packet for transmission.
Event timeout
Enter the timeout period (in seconds) between retransmissions of
unacknowledged events.
Retry Count
Enter the maximum number or event retransmissions allowed by the system.
Dial Attempts
Enter the maximum number of failed dial attempts accepted by the system
before the modem is locked out (prevented from making further attempts to
dial). The lockout period is defined in the option Dial Lockout.
Installation & Configuration Manual
Engineer programming via the browser
Configuring Communications
17
301
A6V10276959
01.05.2016