Vanderbilt SPC42 Series Installation & Configuration Manual page 224

Hide thumbs Also See for SPC42 Series:
Table of Contents

Advertisement

Engineer programming via the browser
17
Configuration
224
Vanderbilt
Restriction
System Option
Set (FTS)
Hide bypass
Battery capacity
Max current
Partset
Partset A
Rename
Partset B
Rename
Alarm
Bell on First
Bell Retrigger
Alert Forbid Set
Web Only
Restore on Unset Enable for alerts to auto clear after 30 seconds in Unset
Antimask Set
!
Antimask Unset
!
Installation & Configuration Manual
Description
If enabled, the bypass messages will no longer be
displayed on keypad.
Total batteries capacity in AH, for panel only (3 - 100 Ah).
You must enter this value and Max current value to view
the remaining battery time on the keypad in the event of
mains failure. This is indicated under the STATUS -
BATTERY - BATT TIME menu.
The total current draw from batteries when mains fail
occurs (30 - 20000 mA). You must enter this value and
the Battery capacity value to view the remaining battery
time on the keypad in the event of mains failure. This is
indicated under the STATUS - BATTERY - BATT TIME
menu.
Enter a new name for your PARTSET A mode (e.g. Night
Mode).
Enter a new name for your PARTSET B mode (e.g. Floor
1 only).
Enable to activate relevant bells/sirens on an
unconfirmed alarm. When this option is disabled, the
relevant bells/sirens will only activate on a confirmed
alarm or if the detector that caused the unconfirmed
alarm is reactivated.
Enable to resound bells/sirens if a second zone activation
is detected (after the bell time has elapsed). If not
checked then the external bells will only trigger once.
If enabled, a user cannot set an area if there is an area or
system alert present on the system.
Note: This option is only available when the Standards ->
Region selected is Switzerland or Security Grade
selected is 'Unrestricted'.
mode.
Note: To comply with PD6662, you must disable this
option.
Select the type of event reported resulting from antimask
detection when panel is Set. Options are Disabled,
Tamper, Trouble or Alarm.
The option can only be configured when the panel is in
'Unrestricted' mode. In Grade 2 or 3 mode, the type of
event reported is in accordance with the standards for the
selected region:
Ireland - Alarm
All other regions - Alarm
Select the type of event reported resulting from antimask
detection when panel is Unset. Options are Disabled,
Tamper, Trouble or Alarm.
The option can only be configured when the panel is in
'Unrestricted' mode. In Grade 2 or 3 mode, the type of
event reported is in accordance with the standards for the
selected region:
Ireland - Disabled
All other regions - Tamper
A6V10276959
01.05.2016