Vanderbilt SPC42 Series Installation & Configuration Manual page 104

Hide thumbs Also See for SPC42 Series:
Table of Contents

Advertisement

Starting the system
14
Configuring start-up settings
104
Vanderbilt
For more details of default zone descriptions see Domestic, Commercial and
Financial mode default settings [➙ 336].
5. Choose the Security Grade of your installation.
6. LANGUAGE View the default languages available on the system. The following
shows the default languages available for each region:
-
IRELAND/UK -English, French, German
-
EUROPE/SWITZERLAND/SPAIN/FRANCE/GERMANY – English, French,
German, Italian, Spanish
-
BELGIUM – English, Dutch, Flemish, French, German
-
SWEDEN – English, Swedish, Danish, French, German
NOTICE
If the system is defaulted, and the REGION is changed on start up, only the
languages that are currently on the system for the previous REGION will be
available for the new REGION.
7. Select the languages you require for your installation. Selected languages are
prefixed with an asterisk (*). To remove, or select, a language, press hash (#)
on the keypad.
 The unselected languages are deleted from the system and will be
unavailable if you default the system.
 To add other languages, refer to the sections on 'Upgrading Languages' for
the keypad, browser and SPC pro.
8. Enter the DATE and TIME.
 The system scans the X-BUS for modems.
9. Enable SPC CONNECT to allow a panel to communicate with
https://www.spcconnect.com once the panel IP address is configured.
10. Enable DHCP to automatically assign an available network IP address to the
panel. If you've enabled SPC CONNECT and DHCP, an SPC CONNECT ATS
is now added to the panel to complete the connection to
https://www.spcconnect.com
11. For DHCP enabled panels, the automatically assigned IP address displays in
the IP ADDRESS menu. If DHCP is not enabled, the default IP address
displays. Choose SELECT to continue. In Engineer Programming mode, under
COMMUNICATIONS, you must manually enter the static IP address for the
panel.
12. Choose the X-BUS addressing mode:
-
MANUAL: is recommended for most installation types, especially when
doing a preconfiguration.
-
AUTO: is recommended only for very small installations.
13. Choose the installation topology: LOOP (Ring) or SPUR (Chain).
 The system scans for the quantity of keypads, expanders, door controllers
and available zone inputs.
14. Press NEXT to scan all X-BUS devices.
Installation & Configuration Manual
A6V10276959
01.05.2016