Vanderbilt SPC42 Series Installation & Configuration Manual page 22

Hide thumbs Also See for SPC42 Series:
Table of Contents

Advertisement

Directives and standards
3
EU directives
22
Vanderbilt
Selecting Grade 2 or Grade 3 selects EN50131 compliance plus any additional
INCERT requirements:
Only an engineer can restore a tamper. For INCERT, this applies across all
grades.
This is normally only a requirement for Grade III En50131.
A tamper on an Inhibited / Isolated zone must be sent to an ARC and displayed
to the user.
For INCERT, tampers are processed for isolated zones. On all other standard
variations, tampers are ignored on isolated zones.
User PIN codes must be defined with more than 4 digits.
Hardware Requirements
The minimum battery capacity for SPC42xx/43xx/52xx/53xx/63xx is 10 Ah / 12
V. If a 10 Ah battery is used, then the battery is biased to the left of the cabinet
and the bottom flap is bent to meet the battery.
Fit jumper (J12) on the battery selector for 17/10 Ah battery use and remove for
7 Ah battery.
The amount of current from Aux output using a 10 Ah battery for
SPC42xx/SPC52xx is:
COMMS
NONE
Standby time
12 h
568 mA
24h
214 mA
30 h
143 mA
60h
2mA
Installation & Configuration Manual
PSTN
GSM
543 mA
438 mA
189 mA
84 mA
118 mA
13 mA
N/A
N/A
PSTN+GSM
413 mA
59 mA
N/A
N/A
A6V10276959
01.05.2016