Vanderbilt SPC42 Series Installation & Configuration Manual page 282

Hide thumbs Also See for SPC42 Series:
Table of Contents

Advertisement

Engineer programming via the browser
17
Configuring Communications
17.10.2.2.2
282
Vanderbilt
Command Profile
ATP Faults
ATP Monitoring Fault
Event Timeout
Minimum Message Lengths
Poll Message
Event Message
Other Message
Add ATP to Analog ARC
If a connection between the SPC panel and RCT (e.g. SPC Com XT) goes down,
FlexC has the ability to switch to a backup ATP connection between the SPC panel
and an Analog ARC. You can configure up to 10 ATPs for each ATS.
1. To configure an ATP between an SPC panel and an Analog ARC, click the
button Add ATP to Analog ARC.
2. Complete the ATP fields described in the table below.
3. Click Save.
Panel Identification
Installation & Configuration Manual
Select the Command Profile which defines
the commands that are allowed on this ATS.
Use ATS Setting
Default Command Profile
Custom Command Profile
Select to generate an ATP fault if the ATP
monitoring fails or an event fails to transmit
on the ATP.
The amount of time that the ATP will keep
trying to transmit the event until the event
fails on the ATP and is passed to the next
ATP.
30 seconds
60 seconds
90 seconds
2 minutes
3 minutes
5 minutes
10 minutes
Minimum length of a poll message.
0 Bytes
64 Bytes
128 Bytes
256 Bytes
512 Bytes
Minimum length of an event and test call
message.
0 Bytes
64 Bytes
128 Bytes
256 Bytes
512 Bytes
Minimum length of connection and
encryption key and update messages.
0 Bytes
64 Bytes
128 Bytes
256 Bytes
512 Bytes
A6V10276959
01.05.2016