Engineer programming via the browser
17
Configuring Communications
17.10.3.1.2
294
Vanderbilt
Editing an ARC filter using SIA or CID
To configure the events on the SPC that will trigger the call to the ARC:
1. Select Select Communications - Reporting - Analog ARC - Edit - Filter..
The following window will be displayed:
2. Configure the following fields:
Check any of the following boxes if you want to initiate a remote call to the ARC to
notify it of the particular event.
Alarms
Alarms are activated.
Alarm Restores
System alarms are restored.
Confirmed Alarms
Alarms confirmed by multiple zones
Alarm Abort
Alarm Abort events. Alarms are aborted after a valid user code is entered via the
keypad after a confirmed or unconfirmed alarm,
Faults
Faults and tampers are activated.
Fault Restores
Fault or tamper alarms are restored.
Settings
System is Set and Unset.
Early/Late
Unscheduled setting and unsetting of the system.
Inhibits
Inhibit and isolate operations are performed on the system.
Door Events
Door events are activated. Only works with SIA protocol.
Installation & Configuration Manual
A6V10276959
01.05.2016