1. Sliding roof sub wire coupler
2. Limit switch 1
3. Limit switch 2
4. White/Black wire terminal
5. Red/Yellow wire terminal
6. Red wire terminal
1. Sliding roof sub wire
(To sliding roof control relay)
Terminal
Check
for
Body
D6
Resistance
ground
Body
D2
Voltage
ground
Body
D8
Resistance
ground
Body
D7
Resistance
ground
Body
D4
Resistance
ground
Body
D10 –
Resistance
ground
Body
D3
Resistance
ground
Body
D9
Resistance
ground
Body
D1
Resistance
ground
Body
D5
Resistance
ground
5) Connect sliding roof switch to sliding roof sub wire.
6) Connect limit switch wires to sliding roof sub wire connector
where they should be connected.
7) Disconnect sliding roof sub wire from sliding roof control relay.
8) Check resistance and voltage at the following condition.
If any of measured condition does not below standard values,
the problem exists on the vehicle, not on the sliding roof control
relay.
Condition
Anytime
Ignition SW OFF
ON
Slide switch OFF
OPEN
Slide switch OFF
CLOSE
Tilt switch OFF
UP
Tilt switch OFF
DOWN
Limit switch 1 OFF
ON
Limit switch 2 OFF
ON
Anytime
Anytime
BODY ELECTRICAL SYSTEM 8-49
Standard
Value
Continuity
0V
10 – 14V
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity