MEASure:COUNter:TOTalize?

Syntax
MEASure:COUNter:TOTalize? (@<ch_list>)
This query command returns a numeric value that represents the totalized
value of the specified counter channel . Multiple responses are separated
by commas.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Remarks
This query requires a channel number to be stated.
Query Returned Format
<value>
U2300A Series USB DAQ Programming Guide
Item
Type
<ch_list>
Numeric
Range of Values
301 through 302
MEASure Subsystem
Default Value
N/A