CONFigure:TIMEbase:ECLocK

Syntax
CONFigure:TIMEbase:ECLocK <clock>
This command is used to set if the time base/clock source is set to
external.

CONFigure:TIMEbase:ECLocK?

The query command returns a numeric value that is set by the user of the
external clock in kHz.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Query Returned Format
<clock> [kHz]
Example
CONFigure:TIMEbase:ECLocK 20000 //Set to external clock of 20 MHz
See Also
CONFigure:TIMEbase:SOURce
U2300A Series USB DAQ Programming Guide
Item
Type
<clock>
Float
Range of Values
10 MHz to 48 MHz
CONFigure Subsystem
Default Value
10000 kHz