SOURce:VOLTage:POLarity

Syntax
SOURce:VOLTage:POLarity <mode>, (@<ch_list>)
This command sets the polarity (unipolar/bipolar) of the output channel.
SOURce:VOLTage[:POLarity]? (@<ch_list>)
The query command returns a string value representing the polarity of the
specified output channel. Multiple responses are separated by commas.
Supported Model
U2351A, U2353A, U2355A, U2356A, U2331A
Parameters
Remarks
• Will force reset voltage level to zero, if the voltage output at negative
• Not supported for U2352A and U2354A.
Query Returned Format
<mode> ::= {UNIPolar|BIPolar}
U2300A Series USB DAQ Programming Guide
Item
Type
<mode>
String
<ch_list>
Numeric
voltage.
Range of Values
UNIPolar: Unipolar
BIPolar: Bipolar
201 through 202
SOURce Subsystem
Default Value
BIPolar
N/A