Measure:counter:data - Agilent Technologies U2300A Series Programming Manual

Multifunction usb data acquisition
Hide thumbs Also See for U2300A Series:
Table of Contents

Advertisement

MEASure:COUNter:DATA?

Syntax
MEASure:COUNter:DATA? (@<ch_list>)
The query command returns a float value based on the SENSe:COUNter
command. This value is the counter value for specific counting mode on
specified counter channel. Multiple responses are separated by commas.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Remarks
This query requires a channel number to be stated.
Query Returned Format
<value>
Example
SENSe:COUNter:FUNCtion TOTalize, (@301)
SENSe:COUNter:FUNCtion FREQuency, (@301)

MEASure:COUNter:DATA? (@301)

See Also
[SENSe:]COUNter:FUNCtion
U2300A Series USB DAQ Programming Guide
Item
Type
<ch_list>
Numeric
Range of Values
301 through 302
MEASure Subsystem
Default Value
N/A
7
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

U2351aU2353aU2354aU2355aU2356aU2331a ... Show all

Table of Contents