[Sense:]Voltage:range - Agilent Technologies U2300A Series Programming Manual

Multifunction usb data acquisition
Hide thumbs Also See for U2300A Series:
Table of Contents

Advertisement

11
SENSe Subsystem

[SENSe:]VOLTage:RANGe

Syntax
[SENSe:]VOLTage:RANGe <range>, (@<ch_list>)
This command is used to set or inquire the analog input (AI) range of the
specified channel. It selects the voltage measurement rangeof the
designated channels.
[SENSe:]VOLTage:RANGe? (@<ch_list>)
The query returns a discrete value representing the voltage value for
current input voltage on each specified analog input channel. Multiple
responses are separated by commas.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Item
Type
<range>
Discrete
<ch_list>
Numeric
Query Returned Format
<range> [V]
100
Range of Values
U2331A:
Unipolar mode: {AUTO|10|5|4|2.5|2.0|1.0|0.5|0.4|0.1}
Bipolar mode: {AUTO|10|5|2.5|2.0|1.25|1.0|0.5|0.25|
0.2|0.05}
U2351A/U2352A/U2353A/U2354A/U2355A/ U2356A:
Unipolar|Bipolar mode: {AUTO|10|5|2.5|1.25}
Single-ended mode:
U2351A/U2352A/U2353A/U2354A: 101-116
U2355A/U2356A/U2331A: 101-164
Differential mode:
U2351A/U2352A/U2353A/U2354A: 101-108
U2355A/U2356A/U2331A: 101-132
Default Value
AUTO
N/A
U2300A Series USB DAQ

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

U2351aU2353aU2354aU2355aU2356aU2331a ... Show all