Source:digital:data:bit - Agilent Technologies U2300A Series Programming Manual

Multifunction usb data acquisition
Hide thumbs Also See for U2300A Series:
Table of Contents

Advertisement

12
SOURce Subsystem
SOURce:DIGital:DATA
Syntax
SOURce:DIGital:DATA:BIT <value>, <bit>, (@<ch_list>)
This command sets or clears individual bits on the specified digital output
channels. The specified channels have to be configured as OUTPut, prior
to sourcing any digital data. Please note that once a channel is
configured as OUTPut, all bits within that channel are set as output.
SOURce:DIGital:DATA:BIT? <bit>, (@<ch_list>)
The query returns a value of 1 (logic High) or 0 (logic Low) for the
specified bit within the specified channel.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Item
Type
<value>
Integer
<bit>
Integer
<ch_list>
Numeric
Remarks
• Prior to using this command, the DIO channel/port has to be configured
• Using this command or query right after
130
:
BIT
Range of Values
0 or 1
Counter Channel 501 and 502: 0 through 7
Counter Channel 503 and 504: 0 through 3
U2351A/U2353A/U2355A/U2356A/U2331A: 501 through 504
Port A: Channel 501
Port B: Channel 502
Port C: Channel 503
Port D: Channel 504
as OUTPut; else a system error will be generated.
system error. This is because after a system reset, the DIO channel/port
is set to INPut.
*RST
will also generate a
U2300A Series USB DAQ Programming Guide
Default Value
0
0
N/A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

U2351aU2353aU2354aU2355aU2356aU2331a ... Show all