MEASure:COUNter:PERiod?

Syntax
MEASure:COUNter:PERiod? (@<ch_list>)
The query command returns a numeric value representing the period
value in ms of the specified counter channel. Multiple responses are
separated by commas.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Remarks
This query requires a channel number to be stated.
Query Returned Format
<value> [ms]
Example
[SENSe:]COUNter:FUNCtion PERiod, (@301)

MEASure:COUNter:PERiod? (@301)

See Also
[SENSe:]COUNter:FUNCtion
MEASure:COUNter:DATA?
U2300A Series USB DAQ Programming Guide
Item
Type
<ch_list>
Numeric
Range of Values
301 through 302
MEASure Subsystem
Default Value
N/A