SOURce:VOLTage:RVOLtage

Syntax
SOURce:VOLTage:RVOLtage <value>
This command used to set the voltage value of the reference voltage once
SOURce:VOLTage:RSouRCe command is set to external.

SOURce:VOLTage:RVOLtage?

The query command returns a numeric value representing voltage value of
the reference voltage in units of volts of the output channels.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Remarks
• Cannot reset to zero.
• Not applicable for U2352A and U2354A.
Query Returned Format
<value> [V]
U2300A Series USB DAQ Programming Guide
Item
Type
<value>
Numeric
Range of Values
Reference voltage value (0 to 10)
SOURce Subsystem
Default Value
10