11
SENSe Subsystem
[SENSe:]VOLTage:POLarity
Syntax
[SENSe:]VOLTage:POLarity <polarity>, (@<ch_list>)
This command is used to set the polarity of the analog input channel.
[SENSe:]VOLTage:POLarity? (@<ch_list>)
The query command returns a string value that represents the mode of
polarity on each specified analog input channel. Multiple responses are
separated by comma.
Supported Model
U2351A, U2352A, U2353A, U2354A, U2355A, U2356A, U2331A
Parameters
Item
<polarity>
<ch_list>
Remarks
• Mutually independent with ROUTe:CHANnel:POLarity.
Query Returned Format
<polarity> ::= {UNIPolar|BIPolar}
102
Type
Range of Values
String
UNIPolar: Unipolar polarity
BIPolar: Bipolar polarity
Numeric
Single-ended mode:
U2351A/U2352A/U2353A/U2354A: 101-116
U2355A/U2356A/U2331A: 101-164
Differential mode:
U2351A/U2352A/U2353A/U2354A: 101-108
U2355A/U2356A/U2331A: 101-132
Default Value
BIPolar
N/A
U2300A Series USB DAQ