Lenovo ThinkSystem NE2552E Application Manual page 304

Flex switch lenovo enterprise network operating system 8.4
Hide thumbs Also See for ThinkSystem NE2552E:
Table of Contents

Advertisement

2. Configure ETS mode as the UFP QoS mode for port INTA10:  
3. Enable UFP on port INTA10:  
4. Globally enable Converged Enhanced Ethernet (CEE):  
5. Globally enable UFP:  
6. Add VLANs to IGMP Snooping and enable IGMP Snooping.
7. Enable IGMPv3 Snooping (optional). 
8. Enable IGMP.
304
NE2552E Application Guide for ENOS 8.4
NE2552E(config)# ufp port INTA10 qos-mode ets
NE2552E(config)# ufp port INTA10 enable
NE2552E(config)# cee enable
NE2552E(config)# ufp enable
NE2552E(config)# ip igmp snoop vlan 101
NE2552E(config)# ip igmp snoop enable
NE2552E(config)# ip igmp snoop igmpv3 enable
NE2552E(config)# ip igmp enable
(Turn on IGMP)

Hide quick links: