5. Set up vPorts on ports 1 and 2.
6. Verify the configuration.
Example 6: UFP with IGMP Configuration
1. Turn on UFP.
2. Configure internal port as UFP.
300
NE2552E Application Guide for ENOS 8.4
NE2552E(config)# ufp port INTA1 enable
NE2552E(config)# ufp port INTA1 vport 1
NE2552E(config-ufp-vport)# network private-vlan trunk
NE2552E(config-ufp-vport)# network default-vlan 100
NE2552E(config-ufp-vport)# network mode trunk
NE2552E(config-ufp-vport)# enable
NE2552E(config-ufp-vport)# exit
NE2552E(config)# ufp port INTA2 enable
NE2552E(config)# ufp port INTA2 vport 1
NE2552E(config-ufp-vport)# network private-vlan promiscuous
NE2552E(config-ufp-vport)# network default-vlan 200
NE2552E(config-ufp-vport)# network mode trunk
NE2552E(config-ufp-vport)# enable
NE2552E(config-ufp-vport)# exit
NE2552E(config)# ufp port INTA3 enable
NE2552E(config)# ufp port INTA3 vport 1
NE2552E(config-ufp-vport)# network private-vlan host
NE2552E(config-ufp-vport)# network default-vlan 300
NE2552E(config-ufp-vport)# network mode trunk
NE2552E(config-ufp-vport)# enable
NE2552E(config-ufp-vport)# exit
NE2552E(config)# vlan 700
NE2552E(config-vlan)# vmember INTA1.1
NE2552E(config-vlan)# vmember INTA2.1
NE2552E(config-vlan)# exit
NE2552E(config)# vlan 701
NE2552E(config-vlan)# vmember INTA1.1
NE2552E(config-vlan)# exit
NE2552E(config)# vlan 702
NE2552E(config-vlan)# vmember INTA1.1
NE2552E(config-vlan)# exit
NE2552E(config)# vlan 703
NE2552E(config-vlan)# vmember INTA1.1
NE2552E(config-vlan)# vmember INTA3.1
NE2552E(config-vlan)# exit
NE2552E(config)# show vlan private-vlan
Follow this procedure to configure IGMP entries on vPorts:
NE2552E(config)# ufp enable
NE2552E(config)# ufp port INTA1 enable
Warning: "Tagging/Trunk-mode" is enabled on UFP port INTA1