11. Configure the vPort default VLAN. 
12. Optionally, you can disable tagging on the vPort.  
13. Specify QoS parameters for the vPort. 
14. Enable vPort. 
15. Enable tagging/trunk mode on external port 1. 
16. Configure VLAN 200 parameters. 
17. Configure VLAN 300 parameters. 
296
NE2552E Application Guide for ENOS 8.4
NE2552E(config_ufp_vport)# network default-vlan 100
NE2552E(config_ufp_vport)# no network default-tag
NE2552E(config_ufp_vport)# qos bandwidth min 15
NE2552E(config_ufp_vport)# qos bandwidth max 95
NE2552E(config_ufp_vport)# enable
NE2552E(config_ufp_vport)# exit
NE2552E(config)# interface port EXT1
NE2552E(config-if)# switchport mode trunk
NE2552E(config-if)# switchport trunk native vlan 100
NE2552E(config-if)# switchport trunk allowed vlan add 200,300
NE2552E(config-if)# exit
NE2552E(config)# vlan 200
NE2552E(config-vlan)# vmember INTA1.1
NE2552E(config-vlan)# vmember INTA2.3
NE2552E(config-vlan)# exit
NE2552E(config)# vlan 300
NE2552E(config-vlan)# vmember INTA1.1
NE2552E(config-vlan)# vmember INTA2.3
NE2552E(config-vlan)# exit
(in percentage)