SNMP Version 1
478
NE2552E Application Guide for ENOS 8.4
To access the SNMP agent on the NE2552E, the read and write community strings 
on the SNMP manager should be configured to match those on the switch. 
The read and write community strings on the switch can be changed using the 
following commands:
NE2552E(config)# snmp-server read-community <1‐32 characters>
‐and‐
NE2552E(config)# snmp-server write-community <1‐32 characters>
The SNMP manager should be able to reach the management interface or any one 
of the IP interfaces on the switch.
For the SNMP manager to receive the SNMPv1 traps sent out by the SNMP agent 
on the switch, configure the trap host on the switch with the following command:  
NE2552E(config)# snmp-server trap-source <trap source IP interface>
NE2552E(config)# snmp-server host <IPv4 address> <trap host community string>
Note: You can use a loopback interface to set the source IP address for SNMP 
traps. Use the following command to apply a configured loopback interface:
snmp-server trap-source loopback
NE2552E(config)#