Example 2: Trunk Mode - Lenovo ThinkSystem NE2552E Application Manual

Flex switch lenovo enterprise network operating system 8.4
Hide thumbs Also See for ThinkSystem NE2552E:
Table of Contents

Advertisement

Example 2: Trunk Mode

1. Turn on UFP. 
2. Configure internal port 1 as UFP. 
3. Configure virtual port. 
4. Configure vPort trunk mode. 
5. Configure vPort default VLAN. 
6. Specify QoS parameters for the vPort. 
7. Enable vPort. 
8. Configure internal port 2 as UFP. 
9. Configure virtual port. 
10. Configure vPort trunk mode. 
© Copyright Lenovo 2018
Following is an example configuration of UFP vPorts in trunk mode. 
NE2552E(config)# ufp enable
NE2552E(config)# ufp port INTA1 enable
Warning: "Tagging/Trunk-mode" is enabled on UFP port INTA1
NE2552E(config)# ufp port INTA1 vport 1
NE2552E(config_ufp_vport)# network mode trunk
NE2552E(config_ufp_vport)# network default-vlan 100
NE2552E(config_ufp_vport)# qos bandwidth min 15
NE2552E(config_ufp_vport)# qos bandwidth max 80
NE2552E(config_ufp_vport)# enable
NE2552E(config_ufp_vport)# exit
NE2552E(config)# ufp port INTA2 enable
Warning: "Tagging/Trunk-mode" is enabled on UFP port INTA2
NE2552E(config)# ufp port INTA2 vport 3
NE2552E(config_ufp_vport)# network mode trunk
(in percentage)