Example 2: Trunk Mode
1. Turn on UFP.
2. Configure internal port 1 as UFP.
3. Configure virtual port.
4. Configure vPort trunk mode.
5. Configure vPort default VLAN.
6. Specify QoS parameters for the vPort.
7. Enable vPort.
8. Configure internal port 2 as UFP.
9. Configure virtual port.
10. Configure vPort trunk mode.
© Copyright Lenovo 2018
Following is an example configuration of UFP vPorts in trunk mode.
NE2552E(config)# ufp enable
NE2552E(config)# ufp port INTA1 enable
Warning: "Tagging/Trunk-mode" is enabled on UFP port INTA1
NE2552E(config)# ufp port INTA1 vport 1
NE2552E(config_ufp_vport)# network mode trunk
NE2552E(config_ufp_vport)# network default-vlan 100
NE2552E(config_ufp_vport)# qos bandwidth min 15
NE2552E(config_ufp_vport)# qos bandwidth max 80
NE2552E(config_ufp_vport)# enable
NE2552E(config_ufp_vport)# exit
NE2552E(config)# ufp port INTA2 enable
Warning: "Tagging/Trunk-mode" is enabled on UFP port INTA2
NE2552E(config)# ufp port INTA2 vport 3
NE2552E(config_ufp_vport)# network mode trunk
(in percentage)