Port Mirroring Behavior

Configuring Port Mirroring

1. Specify the monitoring port, the mirroring port(s), and the port‐mirror direction. 
NE2552E(config)# port-mirroring monitor-port EXT3 mirroring-port EXT1 in
NE2552E(config)# port-mirroring monitor-port EXT3 mirroring-port EXT2 both
2. Enable port mirroring.  
3. View the current configuration. 
548
NE2552E Application Guide for ENOS 8.4
This section describes the composition of monitored packets in the NE2552E, based 
on the configuration of the ports.
Packets mirrored at port egress are mirrored prior to VLAN tag processing and 
may have a different PVID than packets that egress the port toward their actual 
network destination.
Packets mirrored at port ingress are not modified.
The following procedure may be used to configure port mirroring for the example 
shown in Figure 60 on page
NE2552E(config)# port-mirroring enable
NE2552E# show port-mirroring
Port mirroring is enabled
Monitoring Ports
INTA1
INTA2
INTA3
INTA4
...
EXT1
EXT2
EXT3
EXT2, both
EXT4
...
547:
(Display the current settings)
Mirrored Ports
none
none
none
none
none
none
EXT1, in
none