3. Set the SPAR to local domain mode. 
4. Configure SPAR VLAN to 4082. 
5. Add server ports INTA11 through INTA14. 
6. Configure the VLANs for SPAR 2.
7. Create local domain 1, assign VLAN 10, and specify the SPAR ports that are 
8. Create local domain 2, assign VLAN 20, and specify the SPAR ports that are 
9. Create local domain 3, assign VLAN 30, and specify the SPAR ports that are 
10. Enable SPAR 2. 
312
NE2552E Application Guide for ENOS 8.4
NE2552E(config-spar)# domain mode local
NE2552E(config-spar)# domain default vlan 4082
NE2552E(config-spar)# domain default member INTA11-INTA14
Each SPAR has a set of local domains numbered 1 through 32, each of which 
identifies an allowed VLAN. 
The following steps create three local domains: VLAN, 10, 20, and 30 
members of the that VLAN.
NE2552E(config-spar)# domain local 1 vlan 10
NE2552E(config-spar)# domain local 1 member INTA11-INTA14
NE2552E(config-spar)# domain local 1 enable
members of the that VLAN.
NE2552E(config-spar)# domain local 2 vlan 20
NE2552E(config-spar)# domain local 2 member INTA11-INTA14
NE2552E(config-spar)# domain local 2 enable
members of the that VLAN.
NE2552E(config-spar)# domain local 3 vlan 30
NE2552E(config-spar)# domain local 3 member INTA11-INTA14
NE2552E(config-spar)# domain local 3 enable
NE2552E(config-spar)# enable