Controlling with a PLC

As an alternative to operator control from the control panel, you can also control
the SIMATIC VS 130 with a PLC. This makes it possible to train and work almost
automatically.
6.1

Control via the I/O Interface "DI/DO"

6.1.1

Control Signals

You will find the pinning of the I/O interface "DI/DO" in Appendix A.5.
Input Signals
Name
DISA
SEL0
SEL1
SEL2
SEL3
TRN
TRG
RES
Vision Sensor SIMATIC VS 130
A5E00199459-01
Function
Disable: Disable manual control panel input, model selection and train via
digital I/O
Select 0: Code selection: bit 0
Select 1: Code selection bit 1 (if TRN=0) / train code (if TRN=1)
Select 2: Code selection bit 2
Select 3: Code selection bit 3
Train: Train new code
Trigger: An evaluation is started on the positive-going edge
Reset: Reset error
6-1