Ricoh D143 Field Service Manual page 1038

Table of Contents

Advertisement

3. SP Mode Tables
Hour
004
Displays the time (hour) of the last MUSIC execution.
Minute
005
Displays the time (minute) of the last MUSIC execution.
Temperature
006
Displays the temperature of the last MUSIC execution.
007 Execution Result
008 Number of Execution
009 Number of Failure
010 Error Result: M
011 Error Result: C
012 Error Result: Y
[Music A/D Interval]
2198
ADC Trigger Counter
001 ADC Trigger Counter
[Skew Origin Set]
2220
Executes the skew motor initialization in the laser optics unit.
001 M: Skew Motor
002 C: Skew Motor
003 Y: Skew Motor
114
*ENG
[0 to 23 / - / 1 hour/step]
*ENG
[0 to 59 / - / 1 minute/step]
*ENG
[0 to 100 / - / 1 deg/step]
[0 or 1 / - / 1 /step]
*ENG
0: Completed successfully, 1: Failed
*ENG
[0 to 999999 / - / 1 times/step]
*ENG
[0 to 999999 / - / 1 times/step]
*ENG
[0 to 9 / - / 1 /step]
0: Not done
*ENG
1: Completed successfully
2: Cannot detect patterns
3: Fewer lines on the pattern than the target
*ENG
4: Not used
5: Out of the adjustment range
6 to 9: Not used
*ENG
[7.5 to 20 / 10 / 0.1 s/step]
*ENG
-
*ENG
-
*ENG
-

Hide quick links: